DAVIS Energy WeatherLink Uživatelský manuál

Procházejte online nebo si stáhněte Uživatelský manuál pro Databázový software DAVIS Energy WeatherLink. Davis WeatherLink USB Uživatelská příručka

  • Stažení
  • Přidat do mých příruček
  • Tisk

Shrnutí obsahu

Strany 1

VueDavis Instruments, 3465 Diablo Avenue, Hayward, CA 94545-2778 U.S.A. • 510-732-9229 • www.davisnet.com®

Strany 2

8WeatherLinkIP Hardware InstallationTo display the Baud Rate settings on a Vantage Vue console, make sure the data logger is installed and then contin

Strany 3 - Welcome to WeatherLink

9WeatherLinkIP Hardware Installation6. Locate a free Ethernet port on your broadband or DSL router/hub and con-nect the cable to the port.7. Reconnect

Strany 4 - WeatherLink for APRS (# 6540)

10Serial Port Hardware InstallationNote: Because WeatherLinkIP is continuously uploading current weather information to the www.weatherlink.com, leave

Strany 5 - Software Installation

11Serial Port Hardware Installation4. Firmly insert the data logger with serial connector into the receptacle marked EXPANSION inside the battery comp

Strany 6

12Running the Software8. Locate a free serial port on the back of the computer and connect the DB-9 pin connector to the port.9. Insert the cable plug

Strany 7 - USB Hardware Installation

13Station Setuptory where it saves this station’s database and configuration files. The first eight characters of each station name must, therefore, b

Strany 8 - USB Port

14Communication Port SettingsCommunication Port SettingsWeatherLink contains a dialog box for configuring the communication set-tings for your serial,

Strany 9 - How to Display the Baud Rate

15Communication Port SettingsHelp for more detailed instructions. Also, see the WeatherLink Online Help for complete instructions for your modem conne

Strany 10

16Communication Port SettingsFor WeatherLinkIP Communication1. Select TCP/IP from the Communications field. The areas you need to define for TCP/IP co

Strany 11

17Communication Port SettingsFor a Local Connection:1. Click Local Device ID.2. Click Find to find the Device ID for the data logger.3. Click Test to

Strany 12 - Local Connection Installation

Product Number: 6510SER, 6510USB, 6540, 6544, 6550, 6555, 6560 Part Number: 7395.210WeatherLink® for Vantage Pro®, Vantage Pro2™, and Vantage Vue®Rev.

Strany 13

18Updating Previous VersionsStarting with Version 5.2, WeatherLink stores additional sensor data in the weather database. Data files from earlier rele

Strany 14 - Software Setup

19Database ConversionDatabase ConversionIf you have an existing weather database from WeatherLink 5.1 or earlier (including versions of WeatherLink 3

Strany 15 - About the Walkthrough

20Database Conversion2. Select Download in the File menu or click on the Download icon. Weath-erLink does a full download of all data stored in the da

Strany 16 - Communication Port Settings

21Troubleshooting GuideThe following section answers some of the most commonly asked questions about WeatherLink. Please consult this guide and the on

Strany 17 - For USB Communication

22Communications ProblemsUse the loopback connector (the short cable with a phone jack on one end and a red plastic tip on the other) supplied with a

Strany 18

23Communications ProblemsNote: Contact your PC vendor or technical support for more information on these device difficulties.• Hardware device conflic

Strany 19 - Set Transceiver

24Program ProblemsTroubleshooting WeatherLinkIP CommunicationNote: A console using a WeatherLinkIP data logger requires use of the AC-power adapter. B

Strany 20 - Updating Previous Versions

25Program Problems• There is data in your database for the span of the barometer graph.• The time and date of the stored barometer data is correct in

Strany 21 - Database Conversion

26Contacting Davis Technical Support The data I want to see, such as solar radiation, soil moisture, or Temp 2 does not display. Why?All optional sen

Strany 22 - Recalculate THSW Index

27Appendix: Remote Modem InstallationA remote modem installation is a connection from the data logger on the console or Weather Envoy to a modem that

Strany 23 - Troubleshooting Guide

1Welcome to WeatherLink®The data logger and WeatherLink® software let you connect a Davis Vantage Pro®, Vantage Pro2™, or Vantage Vue® console, or Wea

Strany 24 - Loopback

28Appendix: Remote Modem InstallationNote: Failure to remove power to the console before installing the data logger may cause dam-age to the data logg

Strany 25

29Appendix: Remote Modem InstallationTo disconnect the phone connection, select the On-Line icon from the tool bar or select Hang Up from the File men

Strany 26 - Program Problems

Tool bar IconsHot KeysMain Program WindowCtrl-A . . . . . . Set AlarmsCtrl-B . . . . . . View BulletinCtrl-C . . . . . . Station ConfigurationCtrl-G.

Strany 27

2Contents of PackageWeatherLink with Serial Port Connection (# 6510SER)The WeatherLink package with the serial connection contains the following:• Dat

Strany 28 - E-mail Support:

3Computer RequirementsComputer RequirementsWeatherLink software is compatible with computers running Windows 2000 or later.The amount of space necessa

Strany 29

4Software InstallationA series of dialog boxes display, prompting you to complete the Weather-Link installation. The WeatherLink Setup for .NET Framew

Strany 30 - Remote Modem Connection Notes

5USB Hardware Installation3. Review the license agreement, click I agree and click Next. The Choose Destination Location dialog box displays.4. Select

Strany 31 - Toolbar with On-Line Icon

6USB Hardware Installation4. Firmly insert the USB data logger into the large receptacle marked EXPANSION inside the battery compartment. 5. Locate a

Strany 32 - Hot Keys

7USB Hardware Installation7. Reconnect the AC adapter, if present and then reinsert the batteries.The console beeps four times (Vantage Vue) or three

Komentáře k této Příručce

Žádné komentáře