DAVIS UV Sensor Uživatelský manuál Strana 14

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 17
  • Tabulka s obsahem
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 13
Installation and X-320M™ Setup X-MDA-1™ User Manual
2.7 Rain
Sensor Connection: Counter 2
Slope: 0.01
Offset: 0.00
Units: in
2.8 Temperature
The 1-Wire bus is used for compatible digital temperature and humidity sensors. All compatible sensors
have a unique 1-Wire address. The user will need to select the correct address for the corresponding
sensor for each relevant function.
Sensor Connection: 1-Wire Bus
1-Wire Address: (User selects unique sensor ID. Refer to the user manual.)
For Fahrenheit
Slope: 1.0
Offset: 0
Units: ºF
For Celsius
Slope: 0.5555
Offset: -17.7778
Units: ºC
2.9 Relative Humidity
Sensor Connection: 1-Wire Bus
1-Wire Address: (User selects unique sensor ID. Refer to the user manual.)
Slope: 1.00
Offset: 0.00
Units: %RH
2.10 Solar Radiation
Sensor Connection: Analog 1
Slope: 598.799
Offset: 0.00
Units: W/m
2
Note: Solar radiation configuration can be validated at clearskycalculator.com. The calculations assume
a clear sky and should be within about 3% within one hour of solar noon.
Page 14 Xytronix Research & Design, Inc.
Zobrazit stránku 13
1 2 ... 9 10 11 12 13 14 15 16 17

Komentáře k této Příručce

Žádné komentáře