Contact Specifications
The “contact” closure is provided by a photo-coupled MOS device. Because
it is a solid-state device, it is not subject to arcing and contact-welding as are
mechanical relays. However, since it is a solid-state device, it will be
damaged by operation beyond its ratings, which are:
Nominal Load Voltage: 28 V AC or 48 V DC, Maximum
Peak Voltage: ± 60 V, Maximum
Load Current: ± 1.8 A, continuous Maximum at 77°F (25°C),
derated to 0.7 A at 185°F (85°C)
ON Resistance: 0.12 Ohm, Maximum
Note: Upon power up (powering the console or Envoy), the datalogger will
briefly test all four outputs by closing the circuit (turning on the output). It is
recommended that you disconnect any equipment attached to the datalogger
outputs before rebooting the console or Envoy.