Soil Moisture Sensor & Multi-Purpose Temperature
Probe Installation Instructions
For Wireless Leaf & Soil Moisture/Temperature Stations
The WATERMARK Soil Moisture Sensor and the Multi-Purpose Temperature
Probe are for use with the Vantage Pro2 Wireless Leaf & Soil Moisture/Temperature
Station, #6345. Please refer to your Wireless Leaf & Soil Moisture/Temperature
Station manual for more information on how to install and use the sensors.
Installation Procedures
Connecting the Sensors
To extend the sensor cables, see “Extending Sensor Cables” on page 4.
To use a temperature probe for temperature compensation of a soil moisture
sensor, install the sensor pair in corresponding connectors: 1 & 1, 2 & 2, 3 &
3, and 4 & 4.
If no soil temperature probe is used, the station will use a default temp of
75°F (24°C) to compensate the soil moisture readings.
If you are installing a temperature probe that is not providing temperature
compensation for a soil moisture reading, do not use a connector that matches
to any installed soil moisture sensor.
If a soil moister / temperature sensor pair do not use matching connectors, the
soil moisture reading can be off as much as 1% for every 1
°F (0.5°C) error in
the soil temperature.
1. Run the sensor cables up through the grommets on the bottom of the station
housing.
2. Connect soil moisture probes to the SOIL connectors.
3. Connect the temperature probes to the TEMP connectors.
Cable Clam
p
Mount
Leaf Wetness
Sensor Cable
Rubber
Grommets
SENSOR
SENSOR
INTERFACE
INTERFACE
MODULE
MODULE
Cable Clamp
Cable Clam
p
Screw
Temperature Moisture
1 2 3 4 1 2 3 4
Soil Moisture
Sensor Cable
Temperature
Probe Cable
Sensor Cables Enter Station
Housing Through Grommets
Connecting Sensor Cable to
Terminal Block
Zobrazit stránku 0
1 2 3 4

Shrnutí obsahu

Strany 1 - °F (0.5°C) error in

1Soil Moisture Sensor & Multi-Purpose Temperature Probe Installation InstructionsFor Wireless Leaf & Soil Moisture/Temperature StationsThe WAT

Strany 2

24. Secure all sensor cables through the provided cable clamps and then secure the mounts by driving a screw through the clamp into the cable clamp mo

Strany 3 - Moisture Sensor Collar

33. Fill the hole with water and push the sensor down into the hole so it bottoms out. • A length of 1/2” Class 315 PVC pipe (pipe inside diameter = 0

Strany 4

Product Numbers: 6440, 6470Davis Instruments Part Number: 07395.158CSoil Moisture Sensor & Multi-Purpose Temperature Probe Installation Instructio